1-Phase 120/240V Output Receptacle
Maximum total single phase output from the 120/240 volt single phase receptacle is 4.3 kVA (4.3 kW),
18 amps at 240 V.
1-PHASE 120/240V
RECEPTACLE
1-Phase 120V Output Receptacle
Maximum total single phase output from the 120 volt duplex receptacle is 2.2 kVA (2.2 kW), 18 amps
at 120 V.
RECEPTACLE
1-PHASE 120V
11-2 Operation
Danger: Electric Shock
Before connecting or disconnecting load cables to or from the receptacles, turn the circuit
breakers (3-P and 1-P) to the OFF position.
The Earth Grounding Terminal and the enclosure Ground Terminal should always be connected
to an earth ground while operating this equipment.
Grounding connections should be made only with the engine not running.
If the Earth Leakage Circuit Breaker trips on fault, determine the cause and correct it prior to
resetting and shutting the breaker.
23