1-Phase 120/240V Output Receptacle
Maximum total single phase output from the 120/240 volt single phase receptacle is 4.3 kVA (4.3 kW),
18 amps at 240 V.
1-PHASE 120/240V
RECEPTACLE
1-Phase 120V Output Receptacle
Maximum total single phase output from the 120 volt duplex receptacle is 2.2 kVA (2.2 kW), 18 amps
at 120 V.
RECEPTACLE
1-PHASE 120V
11-2 Operation
Danger: Electric Shock
• Before connecting or disconnecting load cables to or from the receptacles, turn the circuit
breakers (3-P and 1-P) to the OFF position.
• The Earth Grounding Terminal and the enclosure Ground Terminal should always be connected
to an earth ground while operating this equipment.
• Grounding connections should be made only with the engine not running.
• If the Earth Leakage Circuit Breaker trips on fault, determine the cause and correct it prior to
resetting and shutting the breaker.
23