Caution: Injuries
Do not plug loads into the receptacles until it has been verified that the load on/off switch is in the
off position.
<Caution>
The AC Volt meter reads three phase output voltage whenever the engine is operating,
regardless of the position of the single phase and three phase breakers.
1. Start the engine in accordance with Section 7-1 Starting.
2. Verify that the Three Phase and Single Phase breakers are in the OFF position.
3. Verify that the load on/off switch is in the off position.
4. Connect the load to the output receptacles.
5. Turn the Three Phase and Single Phase circuit breakers to the ON position.
6. If the electrical demand exceeds the rated output current, the Earth Leakage Circuit Breaker will
trip due to overload.
Caution: Injuries
Turn all load on/off switches to OFF prior to resetting a tripped Earth Leakage Circuit Breaker.
7. After the cause of the overload has been determined and corrected, reset the circuit breaker by
first taking it to the OFF position and then back to the ON position.
12. Simultaneous Use of Welding and Generating
The circuit breakers (3-P and 1-P) are affected only by the AC Generator Output. Simultaneous use of the
welder and generator could lead to overloading the engine. Limit AC Generator power use in accordance
with the following table.
Welding Output AC Power Output
Amperage
Output
Selection
3-Phase
Output
1-Phase
Output
60A Dual 9.0kVA 4.3kVA
120A Dual 8.5kVA 4.3kVA
140A Dual 8.0kVA 4.3kVA
170A Dual 7.5kVA 4.3kVA
240A Single 2.5kVA 2.5kVA
300A Single 2.0kVA 1.5kVA
380A Single 0kVA 0kVA
<Caution>
Eco welding power and AC generator power are not available simultaneously.
Weld quality could be affected when using AC power while welding.