Mufer
This unit must never be operated with a faulty or missing spark arrester or muffler. Make sure the muffler is well secured and
in good condition. A worn or damaged muffler is a fire hazard and may also cause hearing loss.
Spark Plug
Keep the spark plug and wire connections tight and clean.
Fasteners
Make sure nuts, bolts, and screws (except carburetor adjusting screws) are tight.
Daily Maintenance
Prior to each work day, perform the following:
Remove dirt or debris from the
engine, check the cooling fins and air
cleaner for clogging and clean them
as necessary.
Carefully remove any accumulation
of dirt or debris from the muffler or
the fuel tank. Dirt build-up in these
areas could cause engine overheat-
ing, induce premature wear, or cre-
ate a fire hazard.
Check for loose or missing screws or
components. Make sure the cutting
attachment is securely fastened.
Check the entire unit for leaking fuel
or grease.
10-Hour Maintenance
Unscrew
Fastener
Remove and
clean or replace
the element
Every 10 hours of operation (more
frequently in dusty or dirty conditions):
Remove the air cleaner element.
See Figure 26. Clean or replace as
necessary. To clean element: wash it
thoroughly in soap and water. Let it
dry before reinstalling the element.
CAUTION!
Do not operate the unit if the air
cleaner or element is damaged, or if
the element is wet.
Figure 26
Page view 13